A weak potency test often points to a larger process problem.
FDA's final guidance on potency assurance for cellular and gene therapy products, issued November 2, treats potency as the product of a controlled manufacturing system. The release assay still matters. So do source materials, culture conditions, in-process measurements, cryopreservation, reference materials, and the point at which a representative sample is taken.
That framing is especially useful for living products. A cell population can meet an identity panel and remain biologically inconsistent. Viability can look acceptable while a critical function changes. A final sample can also miss damage introduced by a later handling step. The guidance asks developers to map those risks early and tighten the evidence as clinical development advances.
Start with the therapeutic effect and the vulnerable quality attributes
Potency is the capacity of a product to produce a defined result. For a cell therapy, that result might depend on cytotoxicity, secretion, differentiation, tissue formation, receptor signaling, or a combination of functions. FDA recommends identifying potency-related critical quality attributes from the product's intended effect and available mechanism-of-action evidence.
The mechanism may be incomplete during early development. FDA allows a phase-appropriate strategy under that uncertainty. The assay does not have to reproduce the entire therapeutic mechanism. It should measure a biological activity connected to the intended effect and sensitive to a quality attribute that manufacturing can change.
That distinction protects developers from an impossible standard while preserving a useful one. A complex product may act through several pathways in a patient. A release bioassay can focus on a quantifiable step, provided the sponsor explains why that step is relevant and shows that the method detects meaningful variation.
FDA expects most products to have at least one such bioassay. A single measurement may be insufficient when several attributes contribute to potency or when no assay captures the full activity. Complementary biological and physicochemical tests can form a matrix, with each method covering a defined part of the product's function.
Manufacturing controls carry part of the potency burden
The guidance places raw materials and process parameters inside the potency strategy. Growth factors, cytokines, serum replacements, vectors, feeder systems, and other biologically active inputs can vary. Their identity, quality, and activity require controls proportionate to their effect on the product.
Process variables deserve the same treatment. Culture duration, cell density, activation time, media exchange, harvest timing, and hold conditions can shift phenotype and function. A sponsor should establish operating ranges, monitor performance, and understand which deviations alter potency-related attributes.
In-process tests help detect that drift before the final container. FDA cites measures such as cell viability, growth, phenotype, and process-specific functional attributes. These results can support a model of how the product develops across manufacture. They cannot automatically replace a final potency test, because release needs to reflect the product after every step capable of changing potency.
Continued process verification extends the strategy after approval. Lot trends, control charts, deviations, and manufacturing changes can reveal movement that a pass-fail specification hides. A value can remain inside its limit while moving steadily toward the edge. Trending makes that direction visible.
Test after the last consequential step
Sampling location is a central practical issue. If cryopreservation can change potency, FDA recommends testing a representative sample after cryopreservation. Data collected before freezing cannot establish the function of the thawed product on their own.
The same logic applies to formulation, fill, shipping, and device preparation. A developer should ask which steps can change the measured attribute, then place sampling and stability studies accordingly. Comparability work is required when a manufacturing change could shift potency.
Some products make final testing difficult. A destructive bioassay could consume a tissue-engineered unit intended for one patient. The guidance allows testing of a parallel unit, representative sample, or justified surrogate when the relationship to the administered product is demonstrated.
Short shelf life creates a different constraint. FDA describes an approach in which a rapid physicochemical assay supports release while a longer biological assay begins immediately after release. The later result still informs control, investigation, and process understanding. Speed changes the release sequence; it does not erase the need for biological evidence.
A result needs a calibrated range
The document pushes developers away from descriptive potency data. Reporting a number without a lower or upper acceptance criterion does not establish whether a lot is suitable for release. Quantitative specifications should mature from early exploratory ranges into justified limits supported by manufacturing and clinical experience.
Reference materials give those numbers continuity. A stable reference can help compare assay performance across days, analysts, instruments, reagent lots, and sites. FDA recommends qualification and, when appropriate, replacement planning. A living reference material can drift too, so its storage, passage, characterization, and bridging require control.
Assay suitability also changes with phase. Early clinical work may use qualified methods while process knowledge is still developing. Later trials need stronger validation, defined system-suitability controls, and specifications capable of supporting lot-to-lot interpretation. The method should be sufficiently precise, accurate, specific, and robust for its use.
This maturation has a clinical purpose. If early lots differ biologically and the assay cannot resolve the difference, dose-response and safety observations become difficult to interpret. A later pivotal result can fail to support a marketing application because the tested product was not shown to be consistent.
Potency can become a clinical-hold issue
FDA links inadequate potency assurance to participant risk. A product with uncertain biological activity may expose people to an ineffective dose, an unexpectedly strong dose, or a population altered by manufacture. The guidance states that inadequate assurance can contribute to a clinical hold when it creates unreasonable and significant risk.
The risk is not confined to dramatic assay failure. A sponsor may enter phase 2 or phase 3 with an assay that lacks an established relationship to the product's intended effect. Manufacturing changes then become hard to bridge, and clinical results may describe a mixture of biologically different lots.
Early discussion with CBER is therefore a development tool. The guidance encourages sponsors to explore multiple candidate assays and seek feedback while the process remains changeable. Waiting until a pivotal program to define potency can make the assay, process, and clinical history impossible to reconcile cleanly.
What developers should carry forward
The final guidance does not prescribe one universal potency panel. It establishes a chain of reasoning. Define the biological function that matters. Identify the quality attributes and process steps that can disturb it. Use in-process controls to manage those risks. Test a representative final state with quantitative methods and suitable references. Trend the system across lots and re-evaluate it after change.
That chain favors platform thinking. A developer who treats potency as a late analytical task may discover that the assay has no stable process to measure. A team that builds the assay alongside the process can use each to improve the other.
The guidance supersedes FDA's January 2011 document on potency tests. Its scope covers human cellular and gene therapy products licensed under section 351 of the Public Health Service Act. It excludes several product categories, including infectious-disease vaccines, bacteriophages, live biotherapeutics, fecal microbiota products, allergenic products, and invertebrate-derived materials used in wound care.
It is guidance rather than binding law. Its development message is still direct: potency assurance begins well before the release test, and every later claim depends on keeping that chain intact.
Sources and status
This analysis uses FDA's complete final guidance, “Potency Assurance for Cellular and Gene Therapy Products”, issued November 2, 2026, and the agency's guidance record. The recommendations are nonbinding and should be read alongside product-specific discussions with FDA. The hero is an original generated editorial illustration, not agency material or evidence of product approval.